Electronic Expansion Valves · Ammonia

Danfoss AKV / AKVA Electronic Expansion Valves

Danfoss Authorized Distributor (China) Wenzhou Phonetoo is an authorized Danfoss distributor in China — listed in the official Danfoss dealer directory.

AKVA electric expansion valves are designed for ammonia (R717) refrigerating plant — and also approved for R744 (CO2). They are normally controlled by a Danfoss ADAP-KOOL controller.

Valve capacity is regulated by pulse-width modulation (PWM): within a 6-second period the controller switches the coil on and off, and the open/closed time ratio sets the actual capacity (regulation range 10–100%). In some applications AKVA can serve both as expansion valve and solenoid valve.

Supplied as a component programme: separate valve, separate coil (AC or DC, terminal box or cable), and spare parts (upper part, replaceable orifice assembly, filter).

Wenzhou Phonetoo Electromechanical Co., Ltd. is an authorized Danfoss distributor in China. Contact us for availability, pricing and delivery time.

AKVA range

Valve typeCapacity (R717)Orifice sizesConnectionsMOPDMedia temp.
AKVA 104 – 100 kW8Weld, stainless steel18 bar–50 – +60 °C
AKVA 15125 – 500 kW4Flange22 bar–40 – +60 °C
AKVA 20500 – 3150 kW5Weld18 bar–40 – +60 °C

Max. working pressure PS = 42 bar (all types). Ambient: –50 – +50 °C (AKVA 10), –40 – +50 °C (AKVA 15/20). Enclosure max. IP67. Valve seat leakage < 0.02% of kv. Filters: internal replaceable 100 µm (AKVA 10); external 100 µm (AKVA 15/20).

Classifications: DNV, CRN, BV, EAC.

Key features

  • Designed for ammonia (R717) and R744 (CO2)
  • PWM regulation via ADAP-KOOL controllers — no adjustment needed
  • Replaceable orifice assembly; wide regulation range 10–100%
  • Wide range of coils for AC and DC
  • Quick reaction across the whole stated capacity range
  • Can double as expansion valve and solenoid valve in some applications

Applications

  • Flooded evaporation (high/low pressure)
  • Pump separators — for very high safety levels install an EVRAT valve in front of AKVA
  • Direct expansion systems
  • Liquid lines must be dimensioned for AKVA capacity; ensure sufficient subcooling (normally 4 K) to avoid flash gas
The HFC/HCFC version AKV is available on request — this page documents the ammonia range AKVA.

Code numbers

Ordering codes for Danfoss AKVA 10, AKVA 15 and AKVA 20 electric expansion valves. Confirm the exact type and code number in your RFQ and we will quote it.

Rated capacity and ordering

Valve typeRated capacity [kW]Rated capacity [tons]kv-value [m³/h]Connections inlet × outlet [in.]Code no.Connections inlet × outlet [in.]Code no.
AKVA 10-141.10.013/8 × 1/2068F32611/2 × 3/4068F3281
AKVA 10-26.31.80.0153/8 × 1/2068F32621/2 × 3/4068F3282
AKVA 10-3102.80.0223/8 × 1/2068F32631/2 × 3/4068F3283
AKVA 10-4164.50.0383/8 × 1/2068F32641/2 × 3/4068F3284
AKVA 10-5257.10.0553/8 × 1/2068F32651/2 × 3/4068F3285
AKVA 10-64011.40.1033/8 × 1/2068F32661/2 × 3/4068F3286
AKVA 10-76317.90.162––1/2 × 3/4068F3267
AKVA 10-810028.40.251––1/2 × 3/4068F3268
AKVA 15-1125350.25Flange068F5020 (2)––
AKVA 15-2200600.4Flange068F5023 (2)––
AKVA 15-3300900.63Flange068F5026 (2)––
AKVA 15-45001401Flange068F5029 (2)––
AKVA 20-150014011 1/4 × 1 1/4042H2101––
AKVA 20-28002401.61 1/4 × 1 1/4042H2102––
AKVA 20-312503502.51 1/4 × 1 1/4042H2103––
AKVA 20-4200060041 1/2 × 1 1/2042H2104––
AKVA 20-531509006.32 × 2042H2105––

(1) Rated capacities are based on: condensing temperature tc = 32 °C, liquid temperature tl = 28 °C, evaporating temperature te = 5 °C.
(2) Incl. bolts and gaskets but without flanges.

Flange set for AKVA 15

Valve typeConnection [in.]Code no.
AKVA 15-1 to 43/4027N1220
AKVA 15-1 to 41027N1225

Recommended strainer for AKVA 15 / 20

On plants with ammonia and similar industrial plants a strainer must be mounted in front of AKVA 15 and AKVA 20. AKVA 10 has a built-in strainer and an external strainer is not necessary.

Strainer typeCode no. (house)Code no. (strainer insert 100 μm)
FIA 20 D STR148B5343148H3122
FIA 25 D STR148B5443–
FIA 32 D STR148B5544148H3123
FIA 40 D STR148B5625–
FIA 50 D STR148B5713148H3157

Spare parts

Spare partValveTypeCode no.Contents
OrificeAKVA 10AKVA 10-1068F05261 pcs. orifice
1 pcs. Al. gasket
1 pcs. cap for coil
OrificeAKVA 10AKVA 10-2068F0527
OrificeAKVA 10AKVA 10-3068F0528
OrificeAKVA 10AKVA 10-4068F0529
OrificeAKVA 10AKVA 10-5068F0530
OrificeAKVA 10AKVA 10-6068F0531
OrificeAKVA 10AKVA 10-7068F0532
OrificeAKVA 10AKVA 10-8068F0533
FilterAKVA 10 / AKVA 15–068F054010 pcs. filters
10 pcs. Al. gaskets
Upper partAKVA 10 / AKVA 15 / AKVA 20–068F50451 pcs. armature
1 pcs. armature tube
1 pcs. Al. gasket
PistonAKVA 15AKVA 15-1068F52651 pcs. piston assembly
1 pcs. gasket
1 pcs. O-ring
2 pcs. labels
PistonAKVA 15AKVA 15-2068F5266
PistonAKVA 15AKVA 15-3068F5267
PistonAKVA 15AKVA 15-4068F5268
Gasket setAKVA 15Gasket set068F5264Complete gasket set
Orifice setAKVA 15–068F5261Main orifice
Pilot orifice
Al gaskets
O-rings
Gasket
PistonAKVA 20AKVA 20-0.6042H20391 pcs. piston assembly
3 pcs. O-rings
PistonAKVA 20AKVA 20-1042H2040
PistonAKVA 20AKVA 20-2042H2041
PistonAKVA 20AKVA 20-3042H2042
PistonAKVA 20AKVA 20-4042H2043
PistonAKVA 20AKVA 20-5042H2044
Orifice setAKVA 20AKVA 20-0.6068F5270Main orifice, dia. 8 mm
Pilot orifice, dia. 1.8 mm
2 pcs. Al. gaskets
O-ring
Orifice setAKVA 20AKVA 20-1068F5270
Orifice setAKVA 20AKVA 20-2068F5270
Orifice setAKVA 20AKVA 20-3068F5270
Orifice setAKVA 20AKVA 20-4068F5271Main orifice, dia. 14 mm
Pilot orifice, dia. 2.4 mm
2 pcs. Al. gaskets
O-ring
Orifice setAKVA 20AKVA 20-5068F5271
Gasket setAKVA 20Gasket set042H0160Complete gasket set for new and old valves

Coils for AKVA valves (D.C.)

CoilSuitable forCode no.
220 V DC 20 W, standard, with terminal boxAll AKVA valves018F6851
100 V DC 18 W, special, with terminal box, with DIN plugsAll AKVA valves018F6780
230 V DC 18 W, special, with terminal box (1)All AKVA valves018F6781
230 V DC 18 W, special, with DIN plugs (1)All AKVA valves018F6991
230 V DC 18 W, special, with 2.5 m cable (1)All AKVA valves018F6288
230 V DC 18 W, special, with 4.0 m cable (1)All AKVA valves018F6278
230 V DC 18 W, special, with 8.0 m cable (1)All AKVA valves018F6279

(1) Recommended for commercial refrigeration plant.

Coils for AKVA valves (A.C.)

CoilSuitable forCode no. (with terminal box)Code no. (with DIN plugs)
240 V AC 10 W, 50 HzAKVA 10-1 to 10-6, AKVA 15-1 to 15-4018F6702018F6177
240 V AC 10 W, 60 HzAKVA 10-1 to 10-6, AKVA 15-1 to 15-4018F6713–
240 V a.c. 12 W, 50 HzAKVA 10-1 to 10-8, AKVA 15-1 to 15-4, AKVA 20-1 to 20-3018F6802–
220 V AC 10 W, 50 HzAKVA 10-1 to 10-6, AKVA 15-1 to 15-4018F6701018F6176
220 V AC 10 W, 60 HzAKVA 10-1 to 10-6, AKVA 15-1 to 15-4018F6714018F6189
220 V AC 12 W, 50 HzAKVA 10-1 to 10-6, AKVA 15-1 to 15-4, AKVA 20-1 to 20-3018F6801–
220 V a.c. 12 W, 60 HzAKVA 10-1 to 10-6, AKVA 15-1 to 15-4, AKVA 20-1 to 20-3018F6814–
115 V AC 10 W, 50 HzAKVA 10-1 to 10-6, AKVA 15-1 to 15-4018F6711018F6186
115 V AC 10 W, 60 HzAKVA 10-1 to 10-6, AKVA 15-1 to 15-4018F6710018F6185
110 V a.c. 12 W, 50 HzAKVA 10-1 to 10-6, AKVA 15-1 to 15-4, AKVA 20-1 to 20-3018F6811–
110 V a.c. 12 W, 60 HzAKVA 10-1 to 10-6, AKVA 15-1 to 15-4, AKVA 20-1 to 20-3018F6813–
24 V AC 10 W, 50 HzAKVA 10-1 to 10-5, AKVA 15-1 to 15-4018F6707018F6182
24 V AC 10 W, 60 HzAKVA 10-1 to 10-5, AKVA 15-1 to 15-4018F6715–
24 V AC 12 W, 50 HzAKVA 10-1 to 10-5, AKVA 15-1 to 15-4, AKVA 20-1 to 20-5018F6807–
24 V AC 12 W, 60 HzAKVA 10-1 to 10-5, AKVA 15-1 to 15-4, AKVA 20-1 to 20-5018F6815–
24 V AC 20 W, 50 HzAll AKVA valves018F6901–
24 V AC 20 W, 60 HzAll AKVA valves018F6902–

Explosion-proof coils (BI) for AKV / AKVA

Bottom / Frame versionCoil typeSupply voltage [V]Frequency [Hz]MOPD [bar]Cable length [m]Code no.
With BottomBI240C24050 / 60––018Z8585
With BottomBI230C23050 / 60––018Z8586
With BottomBI110C11050 / 60175018Z8587
With BottomBI024C2450 / 60––018Z8588
With BottomBI024D24DC––018Z8589

Valve types covered by the BI “With Bottom” group: AKV, AKVA, EVM, EVRP, EVR, EVRS(T)3, EVRA/EVRAT3, EVRA 25-32-40, ICF 25-50-65.