Electric & Solenoid Valves · Motorized Valves
Danfoss Motor Operated Valves and Actuators Type ICM and ICAD
ICM motor operated valves driven by ICAD actuators regulate expansion in liquid lines (with or without phase change) and control pressure or temperature in dry and wet suction lines and hot-gas lines. Opening and closing forces are balanced, so only two ICAD actuator sizes cover the complete ICM range from DN 20 to DN 150 — a very compact unit.
ICAD 600B / 1200B actuators are controlled via modulating analogue signal (4–20 mA / 2–10 V), digital ON/OFF, or data communication (Modbus RTU / TCP-IP), with an MMI display and Bluetooth mobile-app setup.
Wenzhou Phonetoo Electromechanical Co., Ltd. is an authorized Danfoss distributor in China. Contact us for availability, pricing and delivery time.
Specification
| Item | Value |
| Valve | ICM 20 – 150 |
| Max. working pressure | 65 bar (DN 25–65) / 52 bar (DN 20, DN 100–150) |
| Actuators | ICAD 600B / 1200B |
| Control signals | 4–20 mA / 2–10 V, ON/OFF, Modbus RTU, TCP-IP, Bluetooth app |
| Connections | Butt weld, socket weld, solder, threaded |
| Refrigerants | HCFC, HFC, selected HC, R717 (ammonia), R744 (CO2) |
| Classification | DNV, CRN, BV, EAC |
Key features
- V-port regulating cone for optimum accuracy, especially at part load
- Cavitation-resistant seat (A cones, ICM 25–65) for expansion duty
- Magnetic coupling — true hermetic sealing; PTFE seat for tight shut-off
- Encoder position feedback to Danfoss or third-party controllers
- Manual opening possible via ICAD or multifunction tool
- Convertible to ICS pilot-operated servo valve; function-module overhaul
Confirm the exact ICM size, cone type and ICAD actuator in your RFQ and we will quote it.
Applications
- Liquid-line expansion control and injection control
- Suction pressure / evaporating temperature control
- Hot-gas line control and heat recovery
Code numbers
Ordering codes for Danfoss ICM motorized valves and ICAD actuators. Confirm the exact type and code number in your RFQ and we will quote it.
Complete factory assembled ICM valves (without actuator)
Factory assembled valve body + function module / top cover. Actuator ordered separately. Connection combinations without a code number are available via the parts programme only (valve body + function module ordered separately).
ICM 20
| Type | Connection | Code no. |
| ICM 20-A | 20 D (3⁄4 in.) | 027H1030 |
| ICM 20-A | 25 D (1 in.) | 027H1020 |
| ICM 20-A | 20 A (3⁄4 in.) | 027H1035 |
| ICM 20-A | 20 SOC (3⁄4 in.) | 027H1040 |
| ICM 20-A | 22 SA (7⁄8 in.) | 027H1050 |
| ICM 20-A | 22 SD (7⁄8 in.) | 027H1045 |
| ICM 20-B | 20 D (3⁄4 in.) | 027H1031 |
| ICM 20-B | 25 D (1 in.) | 027H1021 |
| ICM 20-B | 20 A (3⁄4 in.) | 027H1036 |
| ICM 20-B | 20 SOC (3⁄4 in.) | 027H1041 |
| ICM 20-B | 22 SA (7⁄8 in.) | 027H1051 |
| ICM 20-B | 22 SD (7⁄8 in.) | 027H1046 |
| ICM 20-C | 20 D (3⁄4 in.) | 027H1032 |
| ICM 20-C | 25 D (1 in.) | 027H1022 |
| ICM 20-C | 22 SA (7⁄8 in.) | 027H1052 |
| ICM 20-C | 22 SD (7⁄8 in.) | 027H1047 |
| ICM 20-C | 25 A (1 in.) | 027H1025 |
ICM 25
| Type | Connection | Code no. |
| ICM 25-A | 25 D (1 in.) | 027H2000 |
| ICM 25-A | 40 D (1 1⁄2 in.) | 027H2016 |
| ICM 25-A | 35 SD (1 3⁄8 in. SA) | 027H2014 |
| ICM 25-A | 28 SA (1 1⁄8 in.) | 027H2012 |
| ICM 25-A | 22 SA (7⁄8 in.) | 027H2010 |
| ICM 25-A | 28 SD (1 1⁄8 in.) | 027H2008 |
| ICM 25-A | 22 SD (7⁄8 in.) | 027H2006 |
| ICM 25-A | 25 A (1 in.) | 027H2002 |
| ICM 25-A | 25 SOC (1 in.) | 027H2004 |
| ICM 25-B | 25 D (1 in.) | 027H2001 |
| ICM 25-B | 35 SD (1 3⁄8 in. SA) | 027H2015 |
| ICM 25-B | 28 SA (1 1⁄8 in.) | 027H2013 |
| ICM 25-B | 22 SA (7⁄8 in.) | 027H2011 |
| ICM 25-B | 28 SD (1 1⁄8 in.) | 027H2009 |
| ICM 25-B | 22 SD (7⁄8 in.) | 027H2007 |
| ICM 25-B | 25 A (1 in.) | 027H2003 |
| ICM 25-B | 25 SOC (1 in.) | 027H2005 |
ICM 32
| Type | Connection | Code no. |
| ICM 32-A | 32 D (1 1⁄4 in.) | 027H3000 |
| ICM 32-A | 40 D (1 1⁄2 in.) | 027H3012 |
| ICM 32-A | 42 SA (1 5⁄8 in.) | 027H3008 |
| ICM 32-A | 35 SD (1 3⁄8 in. SA) | 027H3006 |
| ICM 32-A | 32 A (1 1⁄4 in.) | 027H3002 |
| ICM 32-A | 32 SOC (1 1⁄4 in.) | 027H3004 |
| ICM 32-B | 32 D (1 1⁄4 in.) | 027H3001 |
| ICM 32-B | 35 SD (1 3⁄8 in. SA) | 027H3007 |
| ICM 32-B | 32 A (1 1⁄4 in.) | 027H3003 |
| ICM 32-B | 32 SOC (1 1⁄4 in.) | 027H3005 |
ICM 40
| Type | Connection | Code no. |
| ICM 40-A | 40 D (1 1⁄2 in.) | 027H4000 |
| ICM 40-A | 50 D (2 in.) | 027H4010 |
| ICM 40-A | 42 SA (1 5⁄8 in.) | 027H4006 |
| ICM 40-A | 42 SD (1 5⁄8 in.) | 027H4008 |
| ICM 40-A | 40 A (1 1⁄2 in.) | 027H4002 |
| ICM 40-A | 40 SOC (1 1⁄2 in.) | 027H4004 |
| ICM 40-B | 40 D (1 1⁄2 in.) | 027H4001 |
| ICM 40-B | 42 SA (1 5⁄8 in.) | 027H4007 |
| ICM 40-B | 42 SD (1 5⁄8 in.) | 027H4009 |
| ICM 40-B | 40 A (1 1⁄2 in.) | 027H4003 |
| ICM 40-B | 40 SOC (1 1⁄2 in.) | 027H4005 |
ICM 50
| Type | Connection | Code no. |
| ICM 50-A | 50 D (2 in.) | 027H5000 |
| ICM 50-A | 65 D (2 1⁄2 in.) | 027H5008 |
| ICM 50-A | 54 SD (2 1⁄8 in. SA) | 027H5006 |
| ICM 50-A | 50 A (2 in.) | 027H5002 |
| ICM 50-A | 50 SOC (2 in.) | 027H5004 |
| ICM 50-B | 50 D (2 in.) | 027H5001 |
| ICM 50-B | 54 SD (2 1⁄8 in. SA) | 027H5007 |
| ICM 50-B | 50 A (2 in.) | 027H5003 |
| ICM 50-B | 50 SOC (2 in.) | 027H5005 |
ICM 65
| Type | Connection | Code no. |
| ICM 65-A | 65 D (2 1⁄2 in.) | 027H6010 |
| ICM 65-A | 65 A (2 1⁄2 in.) | 027H6012 |
| ICM 65-B | 65 D (2 1⁄2 in.) | 027H6001 |
| ICM 65-B | 65 A (2 1⁄2 in.) | 027H6003 |
| ICM 65-B | 67 SA (2 5⁄8 in.) | 027H6007 |
| ICM 65-B | 76 SD (3 in.) | 027H6009 |
| ICM 65-B | 65 SOC (2 1⁄2 in.) | 027H6005 |
ICM 100
| Type | Connection | Code no. |
| ICM 100 | 100 D (4 in.) | 027H7130 |
| ICM 100 | 100 A (4 in.) | 027H7131 |
ICM 125
| Type | Connection | Code no. |
| ICM 125 | 125 D (5 in.) | 027H7150 |
| ICM 125 | 125 A (5 in.) | 027H7151 |
ICM 150
| Type | Connection | Code no. |
| ICM 150 | 150 D (6 in.) | 027H7170 |
| ICM 150 | 150 A (6 in.) | 027H7171 |
ICM function modules / top covers
ICM 20
| Description | Code no. |
| ICM 20-A33 | 027H1186 |
| ICM 20-A | 027H1180 |
| ICM 20-B66 | 027H1194 |
| ICM 20-B | 027H1181 |
| ICM 20-C | 027H1182 |
Includes bolts and O-ring for assembly with ICV valve body; seat and O-ring for mounting the seat in the ICV valve body.
ICM 25
| Description | Code no. |
| ICM 25-A | 027H2180 |
| ICM 25-A33 | 027H2190 |
| ICM 25-B | 027H2181 |
Including gasket and O-rings.
ICM 32
| Description | Code no. |
| ICM 32-A | 027H3180 |
| ICM 32-B | 027H3181 |
Including gasket and O-rings.
ICM 40
| Description | Code no. |
| ICM 40-A | 027H4180 |
| ICM 40-B | 027H4181 |
ICM 40-A including gasket and O-rings.
ICM 50
| Description | Code no. |
| ICM 50-A | 027H5180 |
| ICM 50-B | 027H5181 |
Including gasket and O-rings.
ICM 65
| Description | Code no. |
| ICM 65-A | 027H6180 |
| ICM 65-B | 027H6181 |
Including gasket and O-rings.
ICAD actuators
Cables ordered separately.
| Type | Code no. |
| ICAD 600B with display, Bluetooth, RS485 | 027H0485 |
| ICAD 600B with display, Bluetooth, Ethernet | 027H0486 |
| ICAD 600B, without display, Bluetooth, RS485 | 027H0488 |
| ICAD 600B, without display, Bluetooth, Ethernet | 027H0489 |
| ICAD 1200B, with display, Bluetooth, RS485 | 027H0490 |
| ICAD 1200B, with display, Bluetooth, Ethernet | 027H0491 |
| ICAD 1200B, without display, Bluetooth, RS485 | 027H0493 |
| ICAD 1200B, without display, Bluetooth, Ethernet | 027H0494 |
ICV valve bodies (parts programme)
Connection key: D = Butt-weld DIN; A = Butt-weld ANSI; J = Butt-weld JIS; SOC = Socket weld ANSI; SD = Solder DIN; SA = Solder ANSI; FPT = Female Pipe Thread.
ICV 20
| Connection | Code no. |
| 20 D (3⁄4 in.) | 027H1145 |
| 25 D (1 in.) | 027H1163 |
| 20 A (3⁄4 in.) | 027H1148 |
| 20 SOC (3⁄4 in.) | 027H1151 |
| 16 SA (5⁄8 in.) | 027H1129 |
| 22 SA (7⁄8 in.) | 027H1160 |
| 16 SD (5⁄8 in.) | 027H1132 |
| 22 SD (7⁄8 in.) | 027H1154 |
| 20 FPT (3⁄4 in.) | 027H1157 |
| 25 A (1 in.) | 027H1166 |
ICV 25
| Connection | Code no. |
| 20 D (3⁄4 in.) | 027H2128 |
| 25 D (1 in.) | 027H2120 |
| 32 D (1 1⁄4 in.) | 027H2129 |
| 40 D (1 1⁄2 in.) | 027H2135 |
| 35 SD (1 3⁄8 in. SA) | 027H2134 |
| 28 SA (1 1⁄8 in.) | 027H2126 |
| 22 SA (7⁄8 in.) | 027H2125 |
| 28 SD (1 1⁄8 in.) | 027H2124 |
| 22 SD (7⁄8 in.) | 027H2123 |
| 20 A (3⁄4 in.) | 027H2131 |
| 25 A (1 in.) | 027H2121 |
| 32 A (1 1⁄4 in.) | 027H2130 |
| 20 SOC (3⁄4 in.) | 027H2132 |
| 25 SOC (1 in.) | 027H2122 |
| 20 FPT (3⁄4 in.) | 027H2133 |
| 25 FPT (1 in.) | 027H2127 |
ICV 32
| Connection | Code no. |
| 32 D (1 1⁄4 in.) | 027H3120 |
| 40 D (1 1⁄2 in.) | 027H3125 |
| 42 SA (1 5⁄8 in.) | 027H3127 |
| 42 SD (1 5⁄8 in.) | 027H3128 |
| 35 SD (1 3⁄8 in. SA) | 027H3123 |
| 32 A (1 1⁄4 in.) | 027H3121 |
| 32 SOC (1 1⁄4 in.) | 027H3122 |
| 40 A (1 1⁄2 in.) | 027H3126 |
ICV 40
| Connection | Code no. |
| 40 D (1 1⁄2 in.) | 027H4120 |
| 50 D (2 in.) | 027H4126 |
| 42 SA (1 5⁄8 in.) | 027H4124 |
| 42 SD (1 5⁄8 in.) | 027H4123 |
| 40 A (1 1⁄2 in.) | 027H4121 |
| 40 SOC (1 1⁄2 in.) | 027H4122 |
| 50 A (2 in.) | 027H4127 |
ICV 50
| Connection | Code no. |
| 50 D (2 in.) | 027H5120 |
| 65 D (2 1⁄2 in.) | 027H5124 |
| 54 SD (2 1⁄8 in. SA) | 027H5123 |
| 50 A (2 in.) | 027H5121 |
| 50 SOC (2 in.) | 027H5122 |
| 65 A (2 1⁄2 in.) | 027H5125 |
ICV 65
| Connection | Code no. |
| 65 D (2 1⁄2 in.) | 027H6120 |
| 65 A (2 1⁄2 in.) | 027H6121 |
| 65 J (2 1⁄2 in.) | 027H6122 |
| 80 D (3 in.) | 027H6126 |
| 80 A (3 in.) | 027H6127 |
| 67 SA (2 5⁄8 in.) | 027H6125 |
| 76 SD (3 in.) | 027H6124 |
| 65 SOC (2 1⁄2 in.) | 027H6123 |
ICM top assemblies with FFKM O-ring
| Code no. | Description |
| 027H1175 | ICM 20 A33 top assembly – FFKM |
| 027H1176 | ICM 20 A top assembly – FFKM |
| 027H1177 | ICM 20 B top assembly – FFKM |
| 027H1178 | ICM 20 C top assembly – FFKM |
| 027H1179 | ICM 20 B66 top assembly – FFKM |
| 027H2169 | ICM 25 A33 top assembly – FFKM |
| 027H2170 | ICM 25 A top assembly – FFKM |
| 027H3170 | ICM 32 A top assembly – FFKM |
Frequently asked questions
What is the Danfoss ICM valve?
The ICM is a motorized regulating valve for precise, modulating flow control in industrial refrigeration systems. It is driven by a Danfoss ICAD actuator mounted directly on the valve.
Which actuator does the ICM 50 need?
The ICM works with ICAD actuators. The current series is ICAD B (ICAD 600B / 1200B) — the older ICAD A series (600A/1200A) is discontinued, so new projects should use ICAD B.
Can I buy the ICM valve body without the actuator?
Yes — the ICM valve body and the ICAD actuator can be supplied separately or together. Let us know which combination you need when requesting a quote.
What pressure ratings are available?
ICM valves are available in 65 bar and 52 bar versions depending on size — confirm the rating when ordering.
How is the ICM controlled?
The ICAD actuator positions the valve continuously in response to a modulating control signal, giving stepless flow regulation instead of simple on/off switching.
Where is the ICM typically used?
Typical duties include liquid injection control, suction pressure regulation and condenser pressure control in ammonia and fluorinated refrigeration plants.
Is this a genuine Danfoss product? How long is delivery?
Yes. We are an authorized Danfoss industrial refrigeration distributor in China, listed in Danfoss China’s official authorized dealer directory. All valves are brand-new, genuine stock with valid warranty. We ship from China; express delivery takes about 1–2 weeks to most destinations worldwide.
Can you help select the right ICM + ICAD combination?
Yes — tell us the application, refrigerant, pipe size and control signal, and we will propose the valve size with the matching ICAD actuator.