Danfoss ICS Servo-Operated Main Valves
Danfoss ICS Servo-Operated Main Valves for industrial refrigeration systems, supplied by Wenzhou Phonetoo Electromechanical Co., Ltd. — an authorized Danfoss distributor in China. Contact us for availability, pricing and delivery time.
ICS pilot-operated servo valves are the modular heart of Danfoss industrial refrigeration control. One main valve body accepts a wide range of pilots — solenoid, pressure-regulating, temperature or motorized — to build exactly the function the system needs.
Code numbers
Ordering codes for Danfoss ICS pilot-operated servo valves: valve bodies, function modules and top covers from the parts programme, complete factory assembled valves, ICSX parts and ICV PM valve housings. Confirm the exact type and code number in your RFQ and we will quote it.
Parts programme - ICV valve bodies with different connections
| Valve body | Connection | Code no. |
|---|---|---|
| ICV 25 | 20 D (3/4 in.) | 027H2128 |
| ICV 25 | 25 D (1 in.) | 027H2120 |
| ICV 25 | 32 D (1 1/4 in.) | 027H2129 |
| ICV 25 | 40 D (1 1/2 in.) | 027H2135 |
| ICV 25 | 35 SD (1 3/8 in. SA) | 027H2134 |
| ICV 25 | 28 SA (1 1/8 in.) | 027H2126 |
| ICV 25 | 22 SA (7/8 in.) | 027H2125 |
| ICV 25 | 28 SD (1 1/8 in.) | 027H2124 |
| ICV 25 | 22 SD (7/8 in.) | 027H2123 |
| ICV 25 | 20 A (3/4 in.) | 027H2131 |
| ICV 25 | 25 A (1 in.) | 027H2121 |
| ICV 25 | 32 A (1 1/4 in.) | 027H2130 |
| ICV 25 | 20 SOC (3/4 in.) | 027H2132 |
| ICV 25 | 25 SOC (1 in.) | 027H2122 |
| ICV 25 | 20 FPT (1/2 in.) | 027H2133 |
| ICV 25 | 25 FPT (1 in.) | 027H2127 |
| ICV 32 | 32 D (1 1/4 in.) | 027H3120 |
| ICV 32 | 40 D (1 1/2 in.) | 027H3125 |
| ICV 32 | 42 SA (1 5/8 in.) | 027H3127 |
| ICV 32 | 42 SD (1 5/8 in.) | 027H3128 |
| ICV 32 | 35 SD (1 3/8 in. SA) | 027H3123 |
| ICV 32 | 32 A (1 1/4 in.) | 027H3121 |
| ICV 32 | 32 SOC (1 1/4 in.) | 027H3122 |
| ICV 32 | 40 A (1 1/2 in.) | 027H3126 |
| ICV 40 | 40 D (1 1/2 in.) | 027H4120 |
| ICV 40 | 50 D (2 in.) | 027H4126 |
| ICV 40 | 42 SA (1 5/8 in.) | 027H4124 |
| ICV 40 | 42 SD (1 5/8 in.) | 027H4123 |
| ICV 40 | 40 A (1 1/2 in.) | 027H4121 |
| ICV 40 | 40 SOC (1 1/2 in.) | 027H4122 |
| ICV 40 | 50 A (2 in.) | 027H4127 |
| ICV 50 | 50 D (2 in.) | 027H5120 |
| ICV 50 | 65 D (2 1/2 in.) | 027H5124 |
| ICV 50 | 54 SD (2 1/8 in. SA) | 027H5123 |
| ICV 50 | 50 A (2 in.) | 027H5121 |
| ICV 50 | 50 SOC (2 in.) | 027H5122 |
| ICV 50 | 65 A (2 1/2 in.) | 027H5125 |
| ICV 65 | 65 D (2 1/2 in.) | 027H6120 |
| ICV 65 | 65 A (2 1/2 in.) | 027H6121 |
| ICV 65 | 65 J (2 1/2 in.) | 027H6122 |
| ICV 65 | 80 D (3 in.) | 027H6126 |
| ICV 65 | 80 A (3 in.) | 027H6127 |
| ICV 65 | 67 SA (2 5/8 in.) | 027H6125 |
| ICV 65 | 76 SD (3 in.) | 027H6124 |
| ICV 65 | 65 SOC (2 1/2 in.) | 027H6123 |
D = Butt-weld DIN; A = Butt-weld ANSI; J = Butt-weld JIS; SOC = Socket weld ANSI; SD = Solder DIN; SA = Solder ANSI; FPT = Female Pipe Thread.
Parts programme - Function modules
| Function module | Code no. |
|---|---|
| ICS 25-5 | 027H2201 (1) |
| ICS 25-10 | 027H2202 (1) |
| ICS 25-15 | 027H2203 (1) |
| ICS 25-20 | 027H2204 (1) |
| ICS 25-25 | 027H2200 (1) |
| ICS 32 | 027H3200 (1) |
| ICS 40 | 027H4200 (1) |
| ICS 50 | 027H5200 (1) |
| ICS 65 | 027H6200 (1) |
| ICS 80 | 027H8200 (1) |
(1) Including gasket and O-rings.
Parts programme - Top covers
| Top cover | Code no. |
|---|---|
| Top cover 1 Pilot (ICS 25) | 027H2172 (2) |
| Top cover 3 Pilots (ICS 25) | 027H2173 (3) |
| Top cover 1 Pilot (ICS 32) | 027H3172 (2) |
| Top cover 3 Pilots (ICS 32) | 027H3173 (3) |
| Top cover 1 Pilot (ICS 40) | 027H4172 (2) |
| Top cover 3 Pilots (ICS 40) | 027H4173 (3) |
| Top cover 1 Pilot (ICS 50) | 027H5172 (2) |
| Top cover 3 Pilots (ICS 50) | 027H5173 (3) |
| Top cover 1 Pilot (ICS 65) | 027H6172 (2) |
| Top cover 3 Pilots (ICS 65) | 027H6173 (3) |
| Top cover 1 Pilot (ICS 80) | 027H8192 (2) |
| Top cover 3 Pilots (ICS 80) | 027H8193 (3) |
(2) Including bolts. (3) Including bolts and one blanking plug.
Complete factory assembled valves - ICS 25
| Valve | Pilots | Connection | Code no. |
|---|---|---|---|
| ICS 25-5 | 1 pilot | 20 D (3/4 in.) | 027H2028 |
| ICS 25-5 | 1 pilot | 25 D (1 in.) | 027H2020 |
| ICS 25-5 | 1 pilot | 28 SA (1 1/8 in.) | 027H2026 |
| ICS 25-5 | 1 pilot | 22 SA (7/8 in.) | 027H2025 |
| ICS 25-5 | 1 pilot | 28 SD (1 1/8 in.) | 027H2024 |
| ICS 25-5 | 3 pilots (1) | 20 D (3/4 in.) | 027H2078 |
| ICS 25-5 | 3 pilots (1) | 25 D (1 in.) | 027H2070 |
| ICS 25-5 | 3 pilots (1) | 28 SA (1 1/8 in.) | 027H2076 |
| ICS 25-5 | 3 pilots (1) | 22 SA (7/8 in.) | 027H2075 |
| ICS 25-5 | 3 pilots (1) | 28 SD (1 1/8 in.) | 027H2074 |
| ICS 25-10 | 1 pilot | 20 D (3/4 in.) | 027H2038 |
| ICS 25-10 | 1 pilot | 25 D (1 in.) | 027H2030 |
| ICS 25-10 | 1 pilot | 28 SA (1 1/8 in.) | 027H2036 |
| ICS 25-10 | 1 pilot | 22 SA (7/8 in.) | 027H2035 |
| ICS 25-10 | 1 pilot | 28 SD (1 1/8 in.) | 027H2034 |
| ICS 25-10 | 3 pilots (1) | 20 D (3/4 in.) | 027H2088 |
| ICS 25-10 | 3 pilots (1) | 25 D (1 in.) | 027H2080 |
| ICS 25-10 | 3 pilots (1) | 28 SA (1 1/8 in.) | 027H2086 |
| ICS 25-10 | 3 pilots (1) | 22 SA (7/8 in.) | 027H2085 |
| ICS 25-10 | 3 pilots (1) | 28 SD (1 1/8 in.) | 027H2084 |
| ICS 25-15 | 1 pilot | 20 D (3/4 in.) | 027H2048 |
| ICS 25-15 | 1 pilot | 25 D (1 in.) | 027H2040 |
| ICS 25-15 | 1 pilot | 28 SA (1 1/8 in.) | 027H2046 |
| ICS 25-15 | 1 pilot | 22 SA (7/8 in.) | 027H2045 |
| ICS 25-15 | 1 pilot | 28 SD (1 1/8 in.) | 027H2044 |
| ICS 25-15 | 3 pilots (1) | 20 D (3/4 in.) | 027H2098 |
| ICS 25-15 | 3 pilots (1) | 25 D (1 in.) | 027H2090 |
| ICS 25-15 | 3 pilots (1) | 28 SA (1 1/8 in.) | 027H2096 |
| ICS 25-15 | 3 pilots (1) | 22 SA (7/8 in.) | 027H2095 |
| ICS 25-15 | 3 pilots (1) | 28 SD (1 1/8 in.) | 027H2094 |
| ICS 25-20 | 1 pilot | 20 D (3/4 in.) | 027H2058 |
| ICS 25-20 | 1 pilot | 25 D (1 in.) | 027H2050 |
| ICS 25-20 | 1 pilot | 28 SA (1 1/8 in.) | 027H2056 |
| ICS 25-20 | 1 pilot | 22 SA (7/8 in.) | 027H2055 |
| ICS 25-20 | 1 pilot | 28 SD (1 1/8 in.) | 027H2054 |
| ICS 25-20 | 3 pilots (1) | 20 D (3/4 in.) | 027H2108 |
| ICS 25-20 | 3 pilots (1) | 25 D (1 in.) | 027H2100 |
| ICS 25-20 | 3 pilots (1) | 28 SA (1 1/8 in.) | 027H2106 |
| ICS 25-20 | 3 pilots (1) | 22 SA (7/8 in.) | 027H2105 |
| ICS 25-20 | 3 pilots (1) | 28 SD (1 1/8 in.) | 027H2104 |
| ICS 25-25 | 1 pilot | 20 D (3/4 in.) | 027H2068 |
| ICS 25-25 | 1 pilot | 25 D (1 in.) | 027H2060 |
| ICS 25-25 | 1 pilot | 28 SA (1 1/8 in.) | 027H2066 |
| ICS 25-25 | 1 pilot | 22 SA (7/8 in.) | 027H2065 |
| ICS 25-25 | 1 pilot | 28 SD (1 1/8 in.) | 027H2064 |
| ICS 25-25 | 3 pilots (1) | 20 D (3/4 in.) | 027H2118 |
| ICS 25-25 | 3 pilots (1) | 25 D (1 in.) | 027H2110 |
| ICS 25-25 | 3 pilots (1) | 28 SA (1 1/8 in.) | 027H2116 |
| ICS 25-25 | 3 pilots (1) | 22 SA (7/8 in.) | 027H2115 |
| ICS 25-25 | 3 pilots (1) | 28 SD (1 1/8 in.) | 027H2114 |
| ICS 25-5 | 1 pilot | 22 SD (7/8 in.) | 027H2023 |
| ICS 25-5 | 1 pilot | 20 A (3/4 in.) | 027H2029 |
| ICS 25-5 | 1 pilot | 25 A (1 in.) | 027H2021 |
| ICS 25-5 | 1 pilot | 20 SOC (3/4 in.) | 027H2140 |
| ICS 25-5 | 3 pilots (1) | 22 SD (7/8 in.) | 027H2073 |
| ICS 25-5 | 3 pilots (1) | 20 A (3/4 in.) | 027H2079 |
| ICS 25-5 | 3 pilots (1) | 25 A (1 in.) | 027H2071 |
| ICS 25-5 | 3 pilots (1) | 20 SOC (3/4 in.) | 027H2145 |
| ICS 25-10 | 1 pilot | 22 SD (7/8 in.) | 027H2033 |
| ICS 25-10 | 1 pilot | 20 A (3/4 in.) | 027H2039 |
| ICS 25-10 | 1 pilot | 25 A (1 in.) | 027H2031 |
| ICS 25-10 | 3 pilots (1) | 22 SD (7/8 in.) | 027H2083 |
| ICS 25-10 | 3 pilots (1) | 20 A (3/4 in.) | 027H2089 |
| ICS 25-10 | 3 pilots (1) | 25 A (1 in.) | 027H2081 |
| ICS 25-10 | 3 pilots (1) | 20 SOC (3/4 in.) | 027H2146 |
| ICS 25-15 | 1 pilot | 22 SD (7/8 in.) | 027H2043 |
| ICS 25-15 | 1 pilot | 20 A (3/4 in.) | 027H2049 |
| ICS 25-15 | 1 pilot | 25 A (1 in.) | 027H2041 |
| ICS 25-15 | 1 pilot | 20 SOC (3/4 in.) | 027H2142 |
| ICS 25-15 | 3 pilots (1) | 22 SD (7/8 in.) | 027H2093 |
| ICS 25-15 | 3 pilots (1) | 20 A (3/4 in.) | 027H2099 |
| ICS 25-15 | 3 pilots (1) | 25 A (1 in.) | 027H2091 |
| ICS 25-20 | 1 pilot | 22 SD (7/8 in.) | 027H2053 |
| ICS 25-20 | 1 pilot | 20 A (3/4 in.) | 027H2059 |
| ICS 25-20 | 1 pilot | 25 A (1 in.) | 027H2051 |
| ICS 25-20 | 1 pilot | 20 SOC (3/4 in.) | 027H2143 |
| ICS 25-20 | 3 pilots (1) | 22 SD (7/8 in.) | 027H2103 |
| ICS 25-20 | 3 pilots (1) | 20 A (3/4 in.) | 027H2109 |
| ICS 25-20 | 3 pilots (1) | 25 A (1 in.) | 027H2101 |
| ICS 25-20 | 3 pilots (1) | 20 SOC (3/4 in.) | 027H2148 |
| ICS 25-25 | 1 pilot | 22 SD (7/8 in.) | 027H2063 |
| ICS 25-25 | 1 pilot | 25 A (1 in.) | 027H2061 |
| ICS 25-25 | 1 pilot | 25 SOC (1 in.) | 027H2062 |
| ICS 25-25 | 3 pilots (1) | 22 SD (7/8 in.) | 027H2113 |
| ICS 25-25 | 3 pilots (1) | 25 A (1 in.) | 027H2111 |
| ICS 25-25 | 3 pilots (1) | 25 SOC (1 in.) | 027H2112 |
(1) Including one blanking plug (A+B). Cells marked * in the data sheet are not listed with a code number and must be selected from the parts programme.
Complete factory assembled valves - ICS 32
| Valve | Pilots | Connection | Code no. |
|---|---|---|---|
| ICS 32 | 1 pilot | 32 D (1 1/4 in.) | 027H3020 |
| ICS 32 | 1 pilot | 35 SD (1 3/8 in. SA) | 027H3023 |
| ICS 32 | 1 pilot | 32 A (1 1/4 in.) | 027H3021 |
| ICS 32 | 1 pilot | 32 SOC (1 1/4 in.) | 027H3022 |
| ICS 32 | 3 pilots (1) | 32 D (1 1/4 in.) | 027H3030 |
| ICS 32 | 3 pilots (1) | 35 SD (1 3/8 in. SA) | 027H3033 |
| ICS 32 | 3 pilots (1) | 32 A (1 1/4 in.) | 027H3031 |
| ICS 32 | 3 pilots (1) | 32 SOC (1 1/4 in.) | 027H3032 |
(1) Including one blanking plug (A+B). Cells marked * in the data sheet are not listed with a code number and must be selected from the parts programme.
Complete factory assembled valves - ICS 40
| Valve | Pilots | Connection | Code no. |
|---|---|---|---|
| ICS 40 | 1 pilot | 40 D (1 1/2 in.) | 027H4020 |
| ICS 40 | 1 pilot | 42 SA (1 5/8 in.) | 027H4024 |
| ICS 40 | 1 pilot | 42 SD (1 5/8 in.) | 027H4023 |
| ICS 40 | 1 pilot | 40 A (1 1/2 in.) | 027H4021 |
| ICS 40 | 1 pilot | 40 SOC (1 1/2 in.) | 027H4022 |
| ICS 40 | 3 pilots (1) | 40 D (1 1/2 in.) | 027H4030 |
| ICS 40 | 3 pilots (1) | 42 SA (1 5/8 in.) | 027H4034 |
| ICS 40 | 3 pilots (1) | 42 SD (1 5/8 in.) | 027H4033 |
| ICS 40 | 3 pilots (1) | 40 A (1 1/2 in.) | 027H4031 |
| ICS 40 | 3 pilots (1) | 40 SOC (1 1/2 in.) | 027H4032 |
(1) Including one blanking plug (A+B). Cells marked * in the data sheet are not listed with a code number and must be selected from the parts programme.
Complete factory assembled valves - ICS 50
| Valve | Pilots | Connection | Code no. |
|---|---|---|---|
| ICS 50 | 1 pilot | 50 D (2 in.) | 027H5020 |
| ICS 50 | 1 pilot | 54 SD (2 1/8 in. SA) | 027H5023 |
| ICS 50 | 1 pilot | 50 A (2 in.) | 027H5021 |
| ICS 50 | 1 pilot | 50 SOC (2 in.) | 027H5022 |
| ICS 50 | 3 pilots (1) | 50 D (2 in.) | 027H5030 |
| ICS 50 | 3 pilots (1) | 54 SD (2 1/8 in. SA) | 027H5033 |
| ICS 50 | 3 pilots (1) | 50 A (2 in.) | 027H5031 |
| ICS 50 | 3 pilots (1) | 50 SOC (2 in.) | 027H5032 |
(1) Including one blanking plug (A+B). Cells marked * in the data sheet are not listed with a code number and must be selected from the parts programme.
Complete factory assembled valves - ICS 65 and ICS 80
| Valve | Pilots | Connection | Code no. |
|---|---|---|---|
| ICS 65 | 1 pilot | 65 D (2 1/2 in.) | 027H6020 |
| ICS 65 | 1 pilot | 65 A (2 1/2 in.) | 027H6021 |
| ICS 65 | 1 pilot | 65 SOC (2 1/2 in.) | 027H6023 |
| ICS 65 | 1 pilot | 67 SA (2 5/8 in.) | 027H6025 |
| ICS 65 | 1 pilot | 76 SD (3 in.) | 027H6024 |
| ICS 65 | 3 pilots (1) | 65 D (2 1/2 in.) | 027H6030 |
| ICS 65 | 3 pilots (1) | 65 A (2 1/2 in.) | 027H6021 (5) |
| ICS 65 | 3 pilots (1) | 65 SOC (2 1/2 in.) | 027H6033 |
| ICS 65 | 3 pilots (1) | 67 SA (2 5/8 in.) | 027H6035 |
| ICS 65 | 3 pilots (1) | 76 SD (3 in.) | 027H6034 |
| ICS 80 | 1 pilot | 80 D (3 in.) | 027H8020 |
| ICS 80 | 1 pilot | 80 A (3 in.) | 027H8021 |
| ICS 80 | 3 pilots (1) | 80 D (3 in.) | 027H8030 |
| ICS 80 | 3 pilots (1) | 80 A (3 in.) | 027H8031 |
(1) Including one blanking plug (A+B). (5) The data sheet prints 027H6021 for both 1-pilot and 3-pilot ICS 65 with 65 A connection (code appears twice in the table); we list it exactly as printed in the source PDF. Cells marked * in the data sheet are not listed with a code number and must be selected from the parts programme. NOTE: The capacity of the ICS 80 module can only be achieved when using the valve body with 80 D or A (3 in.) connections. If any other ICV 65 valve body is used the capacity of the complete valve will be reduced by approximately 6%.
Complete factory assembled valves - ICS 100, ICS 125 and ICS 150
| Valve | Connection | Code no. |
|---|---|---|
| ICS 100 (2) | 100 D (4 in.) | 027H7120 |
| ICS 100 (2) | 100 A (4 in.) | 027H7121 |
| ICS 100 (2) | 100 A (4 in.) with 3/8 in. NPT pressure outlet | 027H7122 |
| ICS 125 (2) | 125 D (5 in.) | 027H7140 |
| ICS 125 (2) | 125 A (5 in.) | 027H7141 |
| ICS 125 (2) | 125 A (5 in.) with 3/8 in. NPT pressure outlet | 027H7142 |
| ICS 150 (2) | 150 D (6 in.) | 027H7160 |
| ICS 150 (2) | 150 A (6 in.) | 027H7161 |
| ICS 150 (2) | 150 A (6 in.) with 3/8 in. NPT pressure outlet | 027H7162 |
(2) Including two blanking plugs (A) and one sealing plug (B).
Top covers - ICS 100, ICS 125 and ICS 150
| Top cover | Code no. |
|---|---|
| Top cover complete with manual spindle and gasket, ICS 100 | 027H7123 |
| Top cover complete with manual spindle and gasket, ICS 125 | 027H7143 |
| Top cover complete with manual spindle and gasket, ICS 150 | 027H7163 |
ICV PM flanged valve housings
| Description | Code no. |
|---|---|
| ICV 25 PM Valve housing (3) | 027H2119 |
| ICV 32 PM Valve housing (3) | 027H3129 |
| ICV 40 PM Valve housing (3) | 027H4128 |
| ICV 50 PM Valve housing (4) | 027H5127 |
| ICV 65 PM Valve housing (4) | 027H6128 |
(3) Includes ICV PM valve housing, flange gaskets and flange bolts. (4) Includes ICV PM valve housing, flange gaskets, flange bolts and flange nuts.
ICSX parts programme
The ICSX hot gas powered on/off valve uses the same ICV 32/40/50/65 valve bodies listed above (codes 027H3120, 027H3125, 027H3121, 027H3126, 027H4120, 027H4126, 027H4121, 027H4127, 027H5120, 027H5124, 027H5121, 027H5125, 027H6120, 027H6121, 027H6126, 027H6127) with its own function modules, top covers and external pilot connection:
| Description | Code no. |
|---|---|
| ICSX 32 function module (1) | 027H3900 |
| ICSX 40 function module (1) | 027H4900 |
| ICSX 50 function module (1) | 027H5900 |
| ICSX 65 function module (1) | 027H6900 |
| ICSX 80 function module (1) | 027H8900 |
| ICS 32 top cover 1 pilot (2) | 027H3172 |
| ICS 40 top cover 1 pilot (2) | 027H4172 |
| ICS 50 top cover 1 pilot (2) | 027H5172 |
| ICS 65 top cover 1 pilot (2) | 027H6172 |
| ICS 80 top cover 1 pilot (2) | 027H8172 |
| External pilot connection (incl. damping orifice, D: 1.0 mm) | 027F1048 |
(1) Including gasket and o-rings. (2) Including bolts. NOTE: The capacity of the ICSX 80 module can only be achieved when using the valve body with 80 D or A (3 in.) connections. If any other ICV 65 valve body is used the capacity of the complete valve will be reduced by approximately 6%. NOTE: The ICSX data sheet lists the ICS 80 top cover 1 pilot as 027H8172, while the ICS data sheet lists "Top cover 1 Pilot (ICS 80)" as 027H8192; both codes are reproduced exactly as printed in their respective source PDFs.
Datasheet downloads
Frequently asked questions
What is the Danfoss ICS valve?
The ICS is a pilot-operated servo main valve for industrial refrigeration. Fitted with one or more pilot valves, it controls refrigerant flow by modulation or on/off — used for pressure, temperature and level control duties.
What pressure is the ICS 50 rated for?
The ICS 50 belongs to the small-size range (DN 25–80), rated for a maximum working pressure of 65 bar. Large sizes DN 100–150 are rated 52 bar.
Which pipelines can the ICS be installed in?
The ICS can be applied to any pipeline in the refrigeration system, including liquid lines, suction lines and hot gas lines — selection depends on the pilot valve configuration.
Which refrigerants is the ICS suitable for?
The ICS is applicable to HCFC, HFC, R717 (ammonia) and R744 (CO₂).
How is the ICS controlled?
The main valve is controlled by pilot valve(s): depending on the pilots fitted, it provides modulating control or on/off control in line with the control signal.
What is the difference between ICS and a direct solenoid valve like the EVRA?
The EVRA is a self-contained solenoid valve for simple on/off duty. The ICS is a servo main valve whose function is defined by its pilot valves, so one valve body can serve as a solenoid valve, regulating valve, check valve function and more.
Is this a genuine Danfoss product? How long is delivery?
Yes. We are an authorized Danfoss industrial refrigeration distributor in China, listed in Danfoss China’s official authorized dealer directory. All valves are brand-new, genuine stock with valid warranty. We ship from China; express delivery takes about 1–2 weeks to most destinations worldwide.
Can you help select the right ICS configuration?
Yes — tell us the application (e.g. liquid line solenoid, hot gas defrost, suction pressure regulation), refrigerant, pipe size and pressure rating, and we will propose the valve plus pilot valve combination.